¹«º£²Ê´¬¡¤6600(ÖйúÓÎ)¹Ù·½ÍøÕ¾

  • µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·£¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
    Á¢¼´ÏÂÔØ
    ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨·¢²¼
    Ô¤Ô¼Ö±²¥
    ²úÆ·
    < ·µ»ØÖ÷²Ëµ¥
    ²úÆ·ÖÐÐÄ
    ²úÆ·
    ºÏ×÷»ï°é
    ·µ»ØÖ÷²Ëµ¥
    Ñ¡ÔñÇøÓò/ÓïÑÔ
    RG-S2910C-24GT2XS-HP-E
    RG-S2910C-24GT2XS-HP-E
    RG-S2910C-24GT2XS-HP-E
    RG-S2910C-24GT2XS-HP-E
    ¼ÓÔØÖÐ...0%
    ͼƬ

    24¿ÚǧÕ×µç½ÓÈëPoE½»»»»ú£¨¼Ó2¸öCOMBO¿Ú£©£¬2¸öÍòÕ×ÉÏÐпÚ£¬2¸öÀ©Õ¹²Û£¬RG-S2910C-24GT2XS-HP-E

    ´óÐÍÆóÊÂÒµÔ°ÇøÄÚ¾ÖÓòÍøµÄȫǧÕ×½ÓÈ룬ÉÌҵϵͳµÄǧÕ×½ÓÈë

    ²úÆ·ÌØÐÔ£º

    • ÂÌÉ«½ÚÄÜ£¬±Èͬµµ²úÆ·½ÚÊ¡¹¦ºÄ40%
    • ´îÔØ¹«º£²Ê´¬¡¤6600ÍøÂç×ÔÑÐ¶à½ø³ÌÄ£¿é»¯RGOS11.X²Ù×÷ϵͳ
    • È«ÃæÖ§³ÖSDNÌØÐÔ£¬·ûºÏOpenflow1.3ЭÒé±ê×¼
    • Ö§³ÖTR069ÁãÅäÖÃÉÏÏߣ»·á¸»¶àÑùµÄ¶Ë¿ÚÐÎ̬ѡÔñ
    Á¢¼´×Éѯ

    RG-S2910XS-EϵÁÐÐÂÒ»´ú¸ßЧ½ÚÄܽ»»»»ú

     ÂÌÉ«½ÚÄÜ£¬±Èͬµµ²úÆ·½ÚÊ¡¹¦ºÄ40%

     ´îÔØ¹«º£²Ê´¬¡¤6600ÍøÂç×ÔÑÐ¶à½ø³ÌÄ£¿é»¯RGOS11.X²Ù×÷ϵͳ

     Ö§³ÖSDNÌØÐÔ£¬·ûºÏOpenflow1.3ЭÒé±ê×¼

     Ö§³ÖTR069ÅäÖÃÉÏÏß

     ·á¸»¶àÑùµÄ¶Ë¿ÚÐÎ̬ѡÔñ

    µ±Ïȵļ¼ÊõÖ§³Å

    ÁìÏȵļ¼ÊõÖ§³Å ÁìÏȵļ¼ÊõÖ§³Å

    ÈíÓ²¼æ±¸£¬°²È«¿É¿¿

     ÑÏ¿ÁµÄÔªÆ÷¼þÑ¡ÐÍ

     ³¤´ï3¸öÔ²úÆ·¿É¿¿ÐÔ²âÊÔ

    £¨Èç¸ßµÍΡ¢Õ𶯡¢µç´Å¸ÉÈÅ¡¢ÀËÓ¿¡¢ÐźŲâÊԵȣ©

     Ó²¼þ+Èí¼þ¼¶CPU±£»¤²ßÂÔ

     ¾«×¼Á÷Á¿Í³¼Æ

     ¶ą̀É豸ÐéÄ⻯ͳһ¹Ü¿Ø

    ÈíÓ²¼æ±¸£¬°²È«¿É¿¿

    ¶àÖÖ·½Ê½£¬ÇáËɹÜÀí

    ¶àÖÖ·½Ê½£¬ÇáËɹÜÀí

    ´òÔìÂÌÉ«½ÚÄܵÄÐÂÐÍÉ豸

    Ïà½ÏRG-S5750-SϵÁÐͬÅäÖòúÆ·½ÚÔ¼¹¦ºÄ40%ÒÔÉÏ

    Ïà½Ï±ÈÆäÅäÖõ͵ÄRG-S2900G-EϵÁвúÆ·Ò²ÄܽÚÔ¼¹¦ºÄ10%×óÓÒ

    ´òÔìÂÌÉ«½ÚÄܵÄÐÂÐÍÉ豸

    Òµ½çµ±ÏȵĴ¦ÀíоƬ£¬È·±£ÐÔÄÜÎÞÓÇ

    MACоƬÓëCPU´¦ÀíÆ÷¸ß¶È¼¯³É£¬Îȶ¨ÐԺ㬿ɿ¿ÐԸߣ¬¹¦ºÄ¸üµÍ

    ÄÚ²¿´¦ÀíÐÔÄÜ£º 512£Í£ÂÄڴ棬256£ÍB Flash £¬È·±£É豸ÄÚ²¿´¦ÀíÎÞÆ¿¾±
    Òµ½ç×îеĴ¦ÀíоƬ£¬È·±£ÐÔÄÜÎÞÓÇ

    Áé»îµÄ¶Ë¿ÚÐÎ̬£¬°´ÐèÀ©Õ¹

     µ¥É豸×î¶àÖ§³Ö24¸ö/48¸öǧÕ×µç¿ÚºÍ4¸öÍòÕ×¹â¿Ú£¬
    ¿ÉʵÏÖÈ«ÏßËÙת·¢

     PoE»úÐ;ùÅäÖÃ2¸ö¸´ÓÃÏÂÐйâ¿Ú£¬¹Ì»¯2¸öÍòÕ×¹â¿Ú£¬
    ²¢¿ÉÍâÀ©2¿ÚÍòÕ×£¬Âú×ãÁé»îµÄÀ©Õ¹ÐèÇó

     ¸ßÅäPoE»úÐÍÅ䱸USB½Ó¿Ú£¬¿É½øÐÐÉ豸Éý¼¶¡¢ÈÕÖ¾
    ±¸·Ý¡¢°²È«Ê¶±ð

    Áé»îµÄ¶Ë¿ÚÐÎ̬£¬°´ÐèÀ©Õ¹

    ¶à½ø³ÌÄ£¿é»¯
    ²Ù×÷ϵͳRGOS 11.X

     ×é¼þ(½ø³Ì)»¥Ïà¶ÀÁ¢£¬Ò»¸ö×é¼þ(½ø³Ì)±ÀÀ£²»»áÓ°Ïìµ½
    ÆäËû×é¼þ£¬Ïà±È·ÇÄ£¿é»¯²Ù×÷ϵͳÖ÷»ú¸´Î»µÄ¸ÅÂʽµµÍ
    98%¡£±ÈÈçSTP×é¼þ(½ø³Ì)±ÀÀ££¬²»»áµ¼ÖÂÕû»ú¸´Î»¡£

     ×é¼þ(½ø³Ì)¹ÊÕÏ×ÔÓú£¬±ÈÈçSTP×é¼þ(½ø³Ì)±ÀÀ£ºó£¬¸Ã
    ×é¼þ(½ø³Ì)»á×Ô¶¯ÖØÆô£¨×é¼þÖØÆô£¬¶ø²»ÊÇÕû»úÖØÆô£©£¬
    ²¢»Ö¸´³ÉÕý³£×´Ì¬¼ÌÐøÔËÐС£

    ¶à½ø³ÌÄ£¿é»¯²Ù×÷ϵͳRGOS 11.X

    ÔªÆ÷¼þÑ¡ÐÍÑÏ¿Á£¬Ö»ÎªÆ·ÖʸüºÃ

    ËùÓÐÆ÷¼þ²ÉÓýµ¶îÉè¼Æ£¬ÓÅÏȱ£Ö¤²úÆ·µÄÆ·ÖÊÈçÒ»

     µçÔ´£ºÑ¡ÓÃ-500M ~5000MµÄ¸ßÆ·ÖʵçÔ´£¬ÊÊÓ¦¸÷ÖÖº£°Î»·¾³

     ·çÉÈ£ºÑ¡ÓÿÉÖÇÄܵ÷ËÙ·çÉÈ£¬ÑÓ³¤·çÉÈÊÙÃü

     µçÈÝ£º²ÉÓÃÈÕϵµçÈÝ

    ÔªÆ÷¼þÑ¡ÐÍÑÏ¿Á£¬Ö»ÎªÆ·ÖʸüºÃ

    É豸µÄÎȶ¨ÔËÐÐ
    Ò»Ö±ÊÇÎÒÃÇ×î¹ØÐĵÄ

     Ó²¼þ+Èí¼þ¼¶µÄCPU±£»¤²ßÂÔ£¨Cpu Protection Policy£ºCPP£©
    »ù´¡ÍøÂç±£»¤²ßÂÔ£¨Network Foundation Protection Policy :
    NFPP£©

     ¹«º£²Ê´¬¡¤6600ÍøÂç×ÔÑеÄCPP¼¼ÊõÄܹ»¶Ô·¢ÍùCPUµÄÊýÁ¿Á÷Á¿½øÐзÖÀà»ã
    ×Ü£¬²¢¸³Ó費ͬµÄÓÅÏȼ¶£¬±£Ö¤É豸µÄCPUÎȶ¨ÔËÐС£

     ÅäºÏNFPP¼¼Êõ£¬¿ÉÒÔÓÐЧµÄ·ÀÖ¹¸÷ÖֵĹ¥»÷£¬¾¡¿ÉÄܱ£»¤
    CPU£¬±£Ö¤ÏµÍ³¸÷ÖÖ·þÎñµÄÕý³£ÔËÐУ¬´Ó¶ø´ïµ½ÕûÍøÉ豸¶¼Äܹ»ÎÈ
    ¶¨ÔËÐеÄÄ¿µÄ¡£

    É豸µÄÎȶ¨ÔËÐÐÒ»Ö±ÊÇÎÒÃÇ×î¹ØÐĵÄ

    PoE»úÐÍ£¬ÈÃÄÜÁ¿ÎÞ´¦²»ÔÚ

     Ö§³Ö×Ô¶¯¡¢½ÚÄÜÁ½ÖÖ¹©µç¹ÜÀíģʽ,Ö§³Ö8KVµÄ¶Ë¿Ú
    ·ÀÀ×

     ×Ô´øPoE°´Å¥£¬¿ÉÒ»¼üÇл»Éè¶Ë¿ÚָʾµÆÄ£Ê½£¬ÈÃ
    Äú¶ÔÉ豸ĿǰµÄ¹¤×÷״̬һĿÁËÈ»

     ËùÓж˿ÚÖ§³ÖIEEE802.3afºÍIEEE802.3at ¹©µç£¬
    IEEE802.3at ¿ÉÏòϼæÈݸøIEEE802.3afµÄPDÖÕ
    ¶Ë¹©µç

    PoE»úÐÍ£¬ÈÃÄÜÁ¿ÎÞ´¦²»ÔÚ

    ÎÞÂÛÄÄÖÖÖÕ¶Ë
    ¶¼ÄܼæÈݳöºÃµÄÐÔÄÜ

     Ö§³Öʶ±ð²¢Ê¹Ó÷DZêPDÉ豸

     Í¬Ê±Í¨¹ýЭÒé²ãµÄÓÅ»¯£¬¶Ô½Ó¹«º£²Ê´¬¡¤6600µÄAP²úƷʱÐÔÄÜ»á¸ü¼Ñ

    ÎÞÂÛÄÄÖÖÖն˶¼ÄܼæÈݳö×îºÃµÄÐÔÄÜ

    Ò»Çж¼°´Ðè¶¨ÖÆ

     Ä£¿é»¯µçÔ´Éè¼Æ£¬°´ÐèÑ¡ÔñµçÔ´¹¦ÂÊ£¬×î´ó¿ÉÖ§³Ö48¿ÚPOE+Âú¸ºÔع©µç

     ¿Éͨ¹ý1¡¢2¡¢3¡¢6ÐźŴ«ÊäÏß¶Ô½øÐÐÔ¶³Ì¹©µç

     ¿É°´ÕÕÄúµÄÐèÇó¶¨Ê±¶ÔPoEµÄ¶Ë¿ÚÉÏϵç

     ¿ÉÖ§³ÖPoE²»¼ä¶Ï¹©µç£ºÈÈÖØÆôPoEÖ÷»úÒ²²»»áÓ°Ïì¶ÔÖն˵Ĺ©µç

    Ò»Çж¼°´Ðè¶¨ÖÆ

    VSU¼¼Êõ
    9̨É豸ÇáËÉÐéÄ⻯Ϊ1̨É豸

    ²ÉÓÃVSU3.0ÐéÄ⻯¼¼Êõ£¬¿É½«9̨É豸ÇáËÉÐéÄ⻯Ϊ1̨É豸

     ¶ą̀É豸×÷Ϊһ̨É豸½øÐйÜÀí£¬¹ÜÀíЧÂʸü¸ß

     ±£»¤Óû§Í¶×Ê£¬Á´Â·ÀûÓÃÂʸü¸ß

     ¹ÊÕÏÊÕÁ²Ê±¼ä≤50ms£¬ÍøÂç¸üÎȶ¨

    VSU¼¼Êõ9̨É豸ÇáËÉÐéÄ⻯Ϊ1̨É豸

    SFLOW
    Á÷Á¿·ÖÎö£¬Ò»²½µ½Î»

    ¿ÉÌṩÍêÕûµÄµÚ¶þ²ãµ½µÚËIJãÐÅÏ¢£¬¿ÉÒÔÊÊÓ¦³¬´óÍøÂçÁ÷Á¿»·¾³ÏÂ
    µÄÁ÷Á¿·ÖÎö£¬ÎªÄúÏêϸ¡¢ÊµÊ±µØ·ÖÎö³ÊÏÖÍøÂç´«ÊäÁ÷µÄÐÔÄÜ¡¢Ç÷ÊÆ
    ºÍ´æÔÚµÄÎÊÌâ¡£

    SFLOWÁ÷Á¿·ÖÎö£¬Ò»²½µ½Î»

    0ÅäÖÃÉÏÏߣ¬¼ò»¯²¿Êð

    ȫϵÁÐÉ豸֧³ÖCWMP£¨TR069£©±ê׼ЭÒ飬¿ÉÓëACS
    ·þÎñÆ÷Áª¶¯£¬ÌåÑé¼òµ¥µÄÔËά¹ÜÀí¡£

     ×Ô¶¯ÅäÖúͶ¯Ì¬·þÎñ

     Ö÷³ÌÐò / ÅäÖÃÎļþ¹ÜÀí

     Èí¼þÄ£¿é¹¦ÄܵĹÜÀí

     ×´Ì¬ÐÐΪ¼à¿Ø

     ¹ÊÕÏÕï¶Ï

    0ÅäÖÃÉÏÏߣ¬¼ò»¯²¿Êð

    SDN£¬Á¬½ÓδÀ´

     Ö§³ÖOpenFlow 1.3ЭÒé±ê×¼

     ¿ÉÓ빫º£²Ê´¬¡¤6600ÍøÂç×ÔÑÐSDN controllerÅäºÏ£¬ÇáËɲ¿ÊðSDNÍøÂç

     Ò²¿ÉºóÆÚÕýÍùƽ»¬Éý¼¶µ½SDNÍøÂç

    SDN£¬Á¬½ÓδÀ´

    ÈËÐÔ»¯µÄWeb UI
    ¸ß¿Æ¼¼Ò²¿ÉÒÔÈç´Ë¼òµ¥

    ÈËÐÔ»¯µÄWeb UI ¸ß¿Æ¼¼Ò²¿ÉÒÔÈç´Ë¼òµ¥

    ±ê×¼¼¼ÊõÖ§³Å

     IEEE802.3az(EEE)¹ú¼Ê±ê×¼½ÚÄܼ¼Êõ

     ¼æÈÝÐԺ㬽ÚÄÜЧ¹û¸ü¼Ñ

     ÔÚÒÔÌ«ÍøÁ¬½ÓÏÐÖÃʱ£¬Ê¹¶Ë¿Ú½øÈëµÍ¹¦ºÄģʽ£¬½µµÍ¶Ë¿Ú·¢Éä
    ÐźÅ£¬µ±¶Ë¿ÚÐèҪת·¢Êý¾Ýʱ£¬»á×Ô¶¯»Ö¸´µ½Õý³£¹¤×÷ģʽ£¬
    ÒÔ´Ë´ïµ½½ÚÄܵÄЧ¹û¡£

    ±ê×¼¼¼ÊõÖ§³Å

    ¶à¼¶ÖÇÄܵ÷ËÙ·çÉÈ

    ½ÚÄÜ¡¢»·±£¡¢µÍÔëÒô

    ϵͳ»á¸ù¾Ýµ±Ç°·çÉȵŤ×÷ģʽ£¬×Ô¶¯Îª·çÉÈÖÆ¶¨Ò»¸öĬÈÏµÄÆðʼתËÙ£¬
    Ö®ºóËæ×Å»·¾³Î¶ȵÄÉý¸ßºÍϽµ£¬·çÉȻᰴÕÕÏàÓ¦µÄ¼¶±ð×Ô¶¯Ìá¸ßºÍ½µµÍ
    תËÙ£¬ÉõÖÁÔÚÒ»¶¨Î¶ÈˮƽÏ¿ÉÒÔ´ïµ½
    ¾²ÒôµÄЧ¹û£¬ÒÔ´Ë´ïµ½¸ßЧɢÈȵÄÄ¿µÄ£¬Í¬Ê±È·±£ÔëÒô½µµÍ¡£

    ¶à¼¶ÖÇÄܵ÷ËÙ·çÉÈ

    Ò»Ö±¶¼ÔÚѰÕÒÓÅ»¯µÄ¿Õ¼ä

    ½ÚÄܼ¼ÊõµÄÖ§³Å£¬¹â¿ÚÎÞPHYÉè¼Æ£¬¶Ë¿ÚÐÝÃߣ¬ÖÇÄÜ·çÉȵ÷ËÙ…
    ¶¼ÎªÁËÌåÏÖÔÚ½ÚÄÜЧ¹ûÉÏ

     Ïà½ÏRG-S5750-SϵÁÐͬÅäÖòúÆ·½ÚÔ¼¹¦ºÄ40%ÒÔÉÏ

     Ïà½Ï±ÈÆäÅäÖõ͵ÄRG-S2900G-E²úÆ·Ò²ÄܽÚÔ¼¹¦ºÄ10%×óÓÒ

    Ò»Ö±¶¼ÔÚѰÕÒÓÅ»¯µÄ¿Õ¼ä



    Áé»îµÄÀ©Õ¹ÐÔÄÜ

    RG-S2910XS-EϵÁвúÆ·µÄËùÓеÄSFP+ºÍSFP¶Ë¿Ú¾ù¿ÉÒÔÏòϼæÈݵÍÒ»¼¶µÄ¹â½Ó¿ÚÄ£¿é£»PoEÐͺÅÖ§³Ö±ê×¼µÄ802.3afºÍ802.3atÔ¶³Ì¹©µç±ê×¼£¬ÌṩÄ£¿é»¯Ë«µçÔ´£¬Äܹ»Ö§³ÖËùÓÐÏÂÐж˿ÚPoE+Âú¸ºÔع©µç£»Í¬Ê±Å䱸ÊýÁ¿²»µÈµÄÀ©Õ¹²Û룬¿É¸ù¾ÝÓû§ÐèÒªÁé»îÀ©Õ¹²»Í¬ÊýÁ¿µÄÍòÕ×¹â¿Ú£¬¸ù¾ÝÓû§µÄʹÓó¡¾°Á¿Éí¶¨ÖÆ×¨ÊôµÄÅäÖá£

    ÍêÉÆµÄ°²È«·À»¤²ßÂÔ

    ARP²¡¶¾»ò¹¥»÷ÊÇÍøÂçÖг£¼û£¬Í¬Ê±Ó°Ïì½Ï´óµÄÒ»À๥»÷¡£RG-S2910XS-EϵÁн»»»»úÖ§³Ö¶àÖÖģʽµÄARP·ÀÆÛÆ­¹¦ÄÜ£¬²»ÂÛÊÇÓû§Í¨¹ýDHCP·þÎñÆ÷×Ô¶¯»ñÈ¡µØÖ·£¬»¹ÊÇʹÓù̶¨µÄIPµØÖ·£¬RG-S2910XS-EϵÁÐÄܹ»¼Ç¼Óû§ÕæÊµµÄIP+MACµØÖ·£¬²¢ÔÚ½»»»»ú¶Ë¿ÚÊÕµ½Ö÷»ú·¢Ë͵ÄARP±¨ÎÄʱ£¬½«ARP±¨ÎÄÄÚÈݺͼǼµÄIP+MACµØÖ·½øÐбȶÔ£¬Ö»¶ÔÄÚÈÝÕæÊµµÄARP±¨ÎĽøÐÐת·¢£¬¶ÔÐé¼ÙµÄARP±¨ÎĽøÐжªÆú£¬´Ó¶ø½«ARPÆÛÆ­ÆÁ±ÎÔÚÍøÂçÖ®Í⣬±£ÕÏÍøÂçÓû§ÃâÊÜARP²¡¶¾¹¥»÷¡£

    Ö÷¶¯·ÀÓùÍøÂçÖеĸ÷ÖÖDDOS¹¥»÷£¬ÍøÂçÓÉÓÚÆä¿ª·ÅÐÔ£¬¾­³£ÓÉÓÚ¼ÆËã»ú¸ÐȾ²¡¶¾£¬»òÊǽÓÈëÍøÂçµÄÈËÔ±³öÓÚ¸÷ÖÖÄ¿µÄ¶ÔÍøÂçÉ豸¡¢ÍøÂçÖеķþÎñÆ÷½øÐй¥»÷£¬µ¼ÖÂÍøÂçÎÞ·¨Õý³£Ê¹Ó᣽ϳ£¼ûµÄÈçARP·ººé¹¥»÷µ¼ÖÂÍø¹ØÎÞ·¨ÏìÓ¦ÇëÇó¡¢ICMP·ººé¹¥»÷µ¼ÖÂÍøÂçÉ豸CPU¸ºÔعý¸ßÎÞ·¨Õý³£¹¤×÷£¬DHCPÇëÇ󷺺鹥»÷£¬µ¼ÖÂDHCP·þÎñÆ÷µØÖ·¿Ý½ß£¬Óû§ÎÞ·¨Õý³£»ñÈ¡IPµØÖ··ÃÎÊÍøÂç¡£

    RG-S2910XS-EϵÁÐÌṩҵ½çÏȽøµÄÓ²¼þCPU±£»¤»úÖÆ£ºÌØÓеÄCPU±£»¤²ßÂÔ£¨CPP£¬CPU Protect Policy£©£¬¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷£¬½øÐÐÁ÷Çø·ÖºÍÓÅÏȼ¶¶ÓÁзּ¶´¦Àí£¬²¢¸ù¾ÝÐèҪʵʩ´ø¿íÏÞËÙ£¬³ä·Ö±£»¤CPU²»±»·Ç·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´ÏûºÄ£¬±£ÕÏÁËCPU°²È«£¬³ä·Ö±£»¤Á˽»»»»úµÄ°²È«¡£

    RG-S2910XS-EϵÁÐÌṩÏȽøµÄ»ù´¡ÍøÂç±£»¤²ßÂÔ£¨NFPP£¬Network Foundation Protection Policy£©¼¼Êõ£¬Äܹ»ÏÞÖÆÓû§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÇëÇó±¨ÎÄ¡¢DHCPÇëÇó±¨ÎĵÈÊý¾Ý°üµÄËÙÂÊ£¬¶Ô³¬¹ýÏÞËÙãÐÖµµÄ±¨ÎĽøÐжªÆú´¦Àí£¬ÉõÖÁÄܹ»Ê¶±ð¹¥»÷ÐÐΪ£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§½øÐиôÀë¡£´Ó¶ø±£»¤»ù´¡ÍøÂçÃâÊÜÍøÂç¹¥»÷ÐÐΪµÄÓ°Ï죬±£ÕÏÍøÂçÎȶ¨¡£

    Ö§³ÖDHCP snooping£¬¿ÉÖ»ÔÊÐíÐÅÈζ˿ڵÄDHCPÏìÓ¦£¬·Àֹ˽ÉèDHCP ServerµÄÆÛÆ­£»²¢ÔÚDHCP¼àÌýµÄ»ù´¡ÉÏ£¬Í¨¹ý¶¯Ì¬¼à²âARPºÍ¼ì²éÓû§µÄIP£¬Ö±½Ó¶ªÆú²»·ûºÏ°ó¶¨±íÏîµÄ·Ç·¨±¨ÎÄ£¬ÓÐЧ·À·¶ARPÆÛÆ­ºÍÓû§Ô´IPµØÖ·µÄÆÛÆ­ÎÊÌâ¡£

    ÐéÄâ½»»»µ¥Ôª£¨VSU£¬Virtual Switching Unit£©

    RG-S2910XS-EϵÁвúÆ·Ö§³ÖÐéÄâ½»»»µ¥Ôª£¨VSU£¬Virtual Switching Unit£©¡£Äܹ»½«¶ą̀ÎïÀíÉ豸½øÐл¥Áª£¬Ê¹ÆäÐéÄâΪһ̨Âß¼­É豸£¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet½ø³Ì¡¢µ¥Ò»ÃüÁîÐнӿÚ(CLI)¡¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÅäÖõÈÌØÐÔ½øÐйÜÀí£¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚ¹ÜÀíһ̨É豸£¬µ«ÊÇȴʵÏÖ×Ŷą̀É豸´øÀ´µÄ¹¤×÷ЧÂʺÍʹÓÃÌåÑé¡£

    ¼ò»¯¹ÜÀí£º¹ÜÀíÔ±¿ÉÒÔ¶Ô¶ą̀½»»»»úͳһ¹ÜÀí£¬¶ø²»ÐèÒªÁ¬½Óµ½Ã¿Ì¨½»»»»ú·Ö±ð½øÐÐÅäÖú͹ÜÀí¡£

    ¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨½»»»»ú£¬Í¨¹ý¾ÛºÏÁ´Â·ºÍÍâΧÉ豸Á¬½Ó£¬²»´æÔÚ¶þ²ã»·Â·£¬Ã»±ØÒªÅäÖÃMSTPЭÒ飬¸÷ÖÖ¿ØÖÆÐ­ÒéÊÇ×÷Ϊһ̨½»»»»úÔËÐеÄ¡£

    ºÁÃë¼¶¹ÊÕϻָ´£ºVSUºÍÍâΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·Á¬½Ó£¬Èç¹ûÆäÖÐһ̨É豸»òÕßÒ»Ìõ³ÉÔ±Á´Â·³öÏÖ¹ÊÕÏ£¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄʱ¼äÖ»ÐèÒª50µ½200ºÁÃë¡£

    ¸ßÀ©Õ¹ÐÔ£ºÓû§ÐÂÔöµÄÉ豸¼ÓÈë»òÀ뿪ÐéÄâ»¯ÍøÂçʱ¿ÉÒÔʵÏÖ“ÈȲå°Î”£¬²»Ó°ÏìÆäËûÉ豸µÄÕý³£ÔËÐС£

    ±£»¤Í¶×Ê£ºVSUºÍÍâΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·Á¬½Ó£¬¼ÈÌṩÁËÈßÓàÁ´Â·£¬ÓÖ¿ÉÒÔʵÏÖ¸ºÔؾùºâ£¬³ä·ÖÀûÓÃËùÓÐÍøÂçÉ豸ºÍ´ø¿í×ÊÔ´¡£Í¬Ê±¿ÉÓÃÈÎÒâÐÎ̬µÄÍòÕ×¶Ë¿Úͨ¹ýÈÎÒâµÄÊý¾Ý´«ÊäÏßÀÂ×é³ÉVSUÐéÄâÍøÂçϵͳ£¬²»ÐèÒª¶îÍâÅäÖÃÏßÀ¡¢À©Õ¹¿¨£¬²¢ÇÒûÓж˿ںÍÏßÀÂÖÖÀàµÄÏÞÖÆ£¬±£»¤Óû§µÄͶ×Ê¡£

    ¸ß¿É¿¿ÐÔ

    Ö§³ÖÉú³ÉÊ÷ЭÒéSTP¡¢RSTP¡¢MSTP£¬±£Ö¤¿ìËÙÊÕÁ²£¬Ìá¸ßÈÝ´íÄÜÁ¦£¬±£Ö¤ÍøÂçµÄÎȶ¨ÔËÐкÍÁ´Â·µÄ¸ºÔؾùºâ£¬ºÏÀíʹÓÃÍøÂçͨµÀ£¬ÌṩÈßÓàÁ´Â·ÀûÓÃÂÊ¡£

    Ö§³ÖÐéÄâ·ÓÉÆ÷ÈßÓàЭÒ飨VRRP£©£¬ÓÐЧ±£ÕÏÍøÂçÎȶ¨¡£

    Ö§³Ö¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£¬Rapid Link Detection Protocol£©£¬¿É¿ìËÙ¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ£¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²â¹¦ÄÜ£¬·ÀÖ¹¶Ë¿ÚÏÂÒò˽½ÓHubµÈÉ豸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵÄÏÖÏó¡£

    Ö§³Ö¹«ÓÐÒÔÌ«Íø¶à»·±£»¤¼¼Êõ£¨ERPS£©£¬¹ú¼Ê±ê׼ΪºËÐÄÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝЭÒ飬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·»Ö¸´¶¼¼¯ÖÐÔÚÖ÷¿ØÉ豸ÉϽøÐУ¬·ÇÖ÷¿ØÉ豸ֱ½ÓÏòÖ÷¿ØÉ豸»ã±¨×Ô¼ºµÄÁ´Â·Çé¿ö£¬ÎÞÐè¾­¹ýÆäËû·ÇÖ÷¿ØÉ豸µÄ´¦Àí£¬Òò´Ë»·Â·ÖжÏÒÔ¼°»Ö¸´Ê±¼ä±ÈSTP¿ì¡£»ùÓÚÒÔÉÏÇø±ð£¬ERPSÔÚÀíÏë»·¾³ÏµÄÁ´Â·»Ö¸´ÄÜÁ¦Äܹ»´ïµ½ºÁÃë¼¶¡£

    ÔÚ²»ÆôÓÃSTPµÄÇé¿öÏ£¬¿ÉÒÔͨ¹ý¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£¬Rapid Link Detection Protocol£©Ìṩһ¸ö¿ìËÙÉÏÁ´±£»¤¹¦ÄÜ£¬REUPʹµÃÓû§ÔڹرÕSTPµÄÇé¿öÏ£¬ÈÔÌṩ»ù±¾µÄÁ´Â·ÈßÓ࣬ͬʱÌṩ±ÈSTP¸ü¿ìµÄºÁÃë¼¶¹ÊÕϻָ´¡£

    Èí¼þ¶¨ÒåÍøÂ磨SDN£©

    RG-S2910XS-EϵÁвúÆ·¸úËæÊ±´ú·¢Õ¹£¬Ö§³ÖOpenFlow 1.3£¬¿ÉÒԺ͹«º£²Ê´¬¡¤6600ÍøÂç×ÔÑÐSDN controller Ï໥ÅäºÏ£¬ÇáËÉʵÏÖ´ó¹æÄ£¶þ²ã¼Ü¹¹×éÍø£¬²¢ÇÒÖ§³ÖÕûÍøÆ½»¬Éý¼¶µ½SDNÍøÂ磬ÔÚ´ó·ù¼ò»¯ÍøÂç¹ÜÀíµÄÄѶȵÄͬʱ¿ÉÏÔÖø½µµÍÍøÂçά»¤µÄ³É±¾¡£

    ÂÌÉ«½ÚÄÜ

    RG-S2910XS-EϵÁн»»»»ú³ä·ÖÏàÓ¦¹ú¼ÒÂÌÉ«½ÚÄܵĺÅÕÙ£¬²ÉÓöàÖÖÂÌÉ«½ÚÄܵÄÉè¼ÆÀíÄÕë¶Ô´«Í³½»»»»úÔÚÔëÒô¼°Äܺķ½Ãæ´æÔÚµÄÎÊÌâ½øÐÐÉîÈëÑо¿Ì½Ë÷£¬³ä·Ö½â¾öÁ˽»»»»ú²¿ÊðÔڰ칫»·¾³ÔëÉù´ó¡¢ÒÔ¼°½ÓÈëÉ豸´óÅúÁ¿²¿Êðºó´øÀ´µÄÄܺĹý´óµÄÎÊÌâ¡£

    RG-S2910XS-EϵÁн»»»»ú²ÉÓÃÁËÐÂÒ»´úµÄÓ²¼þ¼Ü¹¹ÒÔ¼°ÏȽøµÄ½ÚÄܵç·Éè¼ÆºÍÔªÆ÷¼þÑ¡ÐÍ¡£É豸µÄÕûÌ幦ºÄ½µµÍÁË40%ÒÔÉÏ£¬¸ü´ó³Ì¶ÈΪÓû§½ÚÊ¡ÄܺÄ£¬Í¬Ê±½µµÍÔëÒôÎÛȾ¡£È«ÏµÁвúÆ·¾ù²ÉÓÃÖáÁ÷±äËÙ·çÉÈÉè¼Æ£¬É豸¿É¸ù¾Ýµ±Ç°µÄζÈÖÇÄÜ¿ØÖÆ·çÉÈתËÙ£¬±£ÕÏÉ豸Îȶ¨¹¤×÷µÄͬʱ£¬½µµÍ¹¦ºÄºÍÔëÉù¡£

    ÔÚPoE¹©µç×éÍø»·¾³ÖУ¬RG-S2910XS-EϵÁвúÆ·¸ù¾Ý²»Í¬Óû§µÄʵ¼ÊÐèÒª£¬PoE¹©µçÌṩ×Ô¶¯Ä£Ê½¡¢½ÚÄÜģʽ¡¢¾²Ì¬Ä£Ê½ÈýÖÖģʽÈÃÓû§Ñ¡Ôñ¡£

    RG-S2910XS-EϵÁн»»»»úÖ§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬¶Ë¿ÚÈç¹ûÔÚÁ¬ÐøÒ»¶Îʱ¼äÖ®ÄÚ¿ÕÏУ¬ÏµÍ³»á½«¸Ã¶Ë¿ÚÉèÖÃΪ½ÚÄÜģʽ£¬µ±Óб¨ÎÄÊÕ·¢Ê±ÔÙͨ¹ý¶¨Ê±·¢Ë͵ļàÌýÂëÁ÷»½ÐѶ˿ڻָ´ÒµÎñ£¬´ïµ½½ÚÄܵÄЧ¹û¡£

    RG-S2910XS-EϵÁвúƷͬʱÂú×ã²ÄÁÏ»·±£Ó밲ȫÐÔµÄÅ·ÃËRoHS±ê×¼£¬·ûºÏSJ/T 11363/11364/11365µÈ¹ú¼ÒÈÏÖ¤ÒªÇó¡£

    ¼òµ¥ÇáËɵÄÍøÂçά»¤

    RG-S2910XS-EϵÁÐÖ§³ÖSNMP¡¢RMON¡¢Syslog¡¢sFLOW¡¢USB±¸·ÝÈÕÖ¾¼°ÅäÖõÈÌØÐÔÀ´½øÐÐÍøÂçµÄÈÕ³£Õï¶Ï¼°Î¬»¤£¬Í¬Ê±¹ÜÀíÔ±¿É²ÉÓÃCLI¡¢WebÍø¹Ü¡¢Telnet¡¢CWMP(TR069)µÈ¶àÑù»¯µÄ¹ÜÀíºÍά»¤·½Ê½¸ü·½±ãÉ豸µÄ¹ÜÀí¡£

    PoEʹÓÃ״̬һĿÁËÈ»£ºÃæ°å×Ô´øÒ»¼ü²é¿´PoE¹©µç״̬¹¦ÄܵÄPoE°´Å¥£¬Çá°´¼´¿É²é¿´É豸µ±Ç°µÄͨÐÅ״̬ºÍ¹©µç״̬£¬ÈÃÄú¶ÔËùÓж˿ÚPoE¹©µçµÄ״̬ÁËÈ»ÓÚÐÄ¡£

    ¼¼Êõ²ÎÊý

    Ó²¼þ¹æ¸ñ

    Ó²¼þ¹æ¸ñ

    RG-S2910-24GT4XS-E

    RG-S2910-48GT4XS-E

    RG-S2910C-24GT2XS-HP-E

    RG-S2910C-48GT2XS-HP-E

    ϵͳ¹æ¸ñ

    °üת·¢ÂÊ

    171Mpps

    207Mpps

    126Mpps

    166Mpps

    ½»»»ÈÝÁ¿

    672Gbps/6.72Tbps

    672Gbps/6.72Tbps

    368Gbps/3.68Tbps

    432Gbps/4.32Tbps

    ½Ó¿Ú¹æ¸ñ

    ¹Ì»¯ÒµÎñ½Ó¿Ú

    24¿Ú10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬

    4¸ö1G/10G SFP+¹â¿Ú£¬

    48¿Ú10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú£¬

    24¿Ú10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬

    2¸ö100/1000M¸´ÓÃSFP¿Ú£¬Ö§³ÖPoE/PoE+Ô¶³Ì¹©µç£¬

    2¸ö1G/10G SFP+¹â¿Ú

    48¿Ú10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬

    2¸ö100/1000M¸´ÓÃSFP¿Ú£¬Ö§³ÖPoE/PoE+Ô¶³Ì¹©µç£¬

    2¸ö1G/10G SFP+¹â¿Ú

    Ä£¿é²å²Û

    0¸öÀ©Õ¹²Û

    0¸öÀ©Õ¹²Û

    2¸öÀ©Õ¹²Û

    2¸öÀ©Õ¹²Û

    À©Õ¹Ä£¿é

    ÎÞ

    ÎÞ

    M2910-01XS

    M2910-01XS

    µçÔ´Ó빦ºÄ

    ¹Ì»¯µçÔ´ÊýÁ¿

    ¹Ì»¯µ¥½»Á÷µçÔ´

    2¸öÀ©Õ¹²Û£¬Ä£¿é»¯Ë«µçÔ´

    ¶î¶¨ÊäÈëµçѹ

    ½»Á÷£¨AC£©ÊäÈ룺

    ¡ñ ¶î¶¨µçѹ·¶Î§£º100V~240V

    ¡ñ ƵÂÊ£º50/60Hz

    ½»Á÷£¨AC£©ÊäÈ룺

    ¡ñ ¶î¶¨µçѹ·¶Î§£º100V~240V

    ¡ñ ƵÂÊ£º50/60Hz

    ×î´óÊäÈëµçѹ

    ½»Á÷£¨AC£©ÊäÈ룺

    ¡ñ ×î´óµçѹ·¶Î§£º90V~264V

    ¡ñ ƵÂÊ£º50/60Hz

    ½»Á÷£¨AC£©ÊäÈ룺

    ¡ñ ×î´óµçѹ·¶Î§£º90V~264V

    ¡ñ ƵÂÊ£º50/60Hz

    ÊäÈëµçѹ

    ¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺

    ÊäÈëµçѹ·¶Î§£º192V~290V

    Ö±Á÷£¨DC£©ÊäÈ룺

    µçѹ·¶Î§£º-36V~-72V

    µäÐ͹¦ºÄ

    ≤24W

    £¨¾²Ì¬≤15.1W£©

    ≤50W

    £¨¾²Ì¬≤32.5W£©

    ´ø24¿ÚPoE+£¬

    СÓÚ850W

    ´ø48¿ÚPoE+£¬

    СÓÚ1700W

    POE¹©µç±ê×¼

    ²»Ö§³Ö

    ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3afºÍ802.3atµÄ¹©µç±ê×¼

    PoE¹¦ÄÜ

    ²»Ö§³Ö

    Ö§³Ö×Ô¶¯¡¢½ÚÄÜ¡¢¾²Ì¬µÄ¹©µç¹ÜÀíģʽ

    Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç

    Ö§³Ö»ùÓÚʱ¼ä²ßÂÔ¶ÔPoE¶Ë¿Ú¶¨Ê±ÉÏϵç

    Ö§³Ö¶Ë¿ÚÓÅÏȼ¶

    PoEÉ豸֧³Ö¶Ñµþ¹¦ÄÜ

    ³ß´çÓëÖØÁ¿

    ²úÆ·³ß´ç£¨¿í×Éî׸ߣ©

    V1.XXÓ²¼þ°æ±¾£º443mm×268mm×44.5mm

    V2.XXÓ²¼þ°æ±¾£º440mm×220mm×44mm

    440mm×320mm×44mm

    440mm×360mm×44mm

    »·¾³Óë¿É¿¿ÐÔ

    ¹¤×÷ζÈ

    0¡æ~50¡æ

    ´æ´¢Î¶È

    -40¡æ~70¡æ

    ·çÉÈ¼à¿Ø

    Ö§³Ö·çÉȵ÷ËÙ¼°·çÉȹÊÕϸ澯¹¦ÄÜ

    ¹¤×÷ʪ¶È

    10%~90%RH

    ´æ´¢Êª¶È

    5%~95%RH

    ͨÐŽӿڷÀÀ×

    ¹²Ä£10kV£¬²îÄ£500V(V2.XX¼°ÒÔÉÏÓ²¼þ°æ±¾)

    ¹²Ä£6kV

    µçÔ´½Ó¿Ú·ÀÀ×

    ¹²Ä£6kV£¬²îÄ£6kV

     

    Èí¼þ¹æ¸ñ

    ¶þ²ãÌØÐÔ

    RG-S2910-24GT4XS-E

    RG-S2910-48GT4XS-E

    RG-S2910C-24GT2XS-HP-E

    RG-S2910C-48GT2XS-HP-E

    802.1Q VLAN

    Ö§³Ö4K 802.1Q VLAN

    Ö§³ÖPort based VLAN

    Ö§³ÖMAC based VLAN

    Ö§³ÖProtocol based VLAN

    Ö§³ÖPrivate VLAN

    Ö§³ÖVoice VLAN

    Ö§³ÖPrivate VLAN

    Ö§³ÖIP subnet-based VLAN

    Ö§³ÖGVRP

    QinQ

    Ö§³Ö»ù±¾QinQ

    Ö§³ÖÁé»îQinQ

    ACL

    Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©

    Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©

    Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©

    Ö§³Ö»ùÓÚʱ¼äACL

    Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢Ð­ÒéÀàÐÍ¡¢Ê±¼äµÈÁé»î×éºÏµÄÓ²¼þACL£©

    Ö§³ÖACL80

    Ö§³ÖIPv6 ACL

    Ö§³ÖÈ«¾ÖACL

    Ö§³ÖACLÖØ¶¨Ïò

    QoS

    Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð

    Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ

    Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà

    ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ

    Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È

    Mirror

    Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ

    Ö§³ÖRSPAN¡¢ERSPAN

    Ö§³Ö»ùÓÚÁ÷µÄ±¾µØ¡¢Ô¶³Ì¾µÏñ

    DHCP

    Ö§³ÖDHCP Server

    Ö§³ÖDHCP Client

    Ö§³ÖDHCP Snooping

    Ö§³ÖDHCP Relay

    Ö§³ÖIPv6 DHCP Snooping

    Ö§³ÖIPv6 DHCP Client

    Ö§³ÖIPv6 DHCP Relay

    °²È«ÌØÐÔ

    Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

    Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

    ¹ýÂË·Ç·¨µÄMACµØÖ·

    Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x

    Ö§³ÖMAB

    Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤

    Ö§³ÖARP-Check

    Ö§³ÖDAI

    Ö§³ÖARP±¨ÎÄÏÞËÙ

    Ö§³Ö·ÀÍø¹ØARPÆÛÆ­

    Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ

    ¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤

    Ö§³ÖRADIUS ºÍ TACACS+

    É豸µÇ½¹ÜÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©

    Ö§³ÖSSH ºÍ SSH V2.0

    Ö§³ÖBPDU Guard

    Ö§³ÖIP SOURCE Guard

    Ö§³ÖCPP¡¢NFPP

    Ö§³Ö¶Ë¿Ú±£»¤

    ÏßÀ¼ì²â

    Ö§³ÖÏßÀ¼ì²â

    EEE

    Ö§³ÖIEEE 802.3az±ê×¼µÄ EEE½ÚÄܼ¼Êõ£ºµ±EEEʹÄÜʱ£¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ£¬´ïµ½Á˽ÚÄܵÄÄ¿µÄ¡£

    »·ÍøÐ­Òé

    Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS£¬Çл»Ê±¼ä≤50ms£¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·ÍêÃÀ¼æÈÝ

    ¶Ë¿ÚÐÝÃß

    Ö§³Ö¶Ë¿ÚÐÝÃß

     


    Èý²ãÌØÐÔ

    RG-S2910-24GT4XS-E

    RG-S2910-48GT4XS-E

    RG-S2910C-24GT2XS-HP-E

    RG-S2910C-48GT2XS-HP-E

    IP·ÓÉ

    IPv4/IPv6 ¾²Ì¬Â·ÓÉ

    RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3

    Routing Policy

    IPv6

    »ù´¡Ð­Òé

    IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖЭÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ

    VSUÌØÐÔ

    Ö§³ÖVSUÐéÄ⻯¼¼Êõ

    Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ

    Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·À¦°ó

    Ö§³Öͨ¹ý±ê×¼ÒµÎñ¿ÚʵÏÖÐéÄ⻯£¨·Ç¶Ñµþ²å¿¨£¬²»Õ¼ÓÃÀ©Õ¹²Û룩

    ¼«¼òÍøÂç

    Ö§³ÖÓëºËÐÄÉ豸¹¹½¨´ó¶þ²ãÍøÂ磬ͨ¹ýVSUºÍVSDµÈÐéÄ⻯¼¼ÊõʵÏÖÍøÂç×ÊÔ´³Ø»¯£¬Ö»ÐèÒª¹ÜÀíºËÐÄÉ豸£¬´Ó¶ø¼ò»¯ºáÏòºÍ×ÝÏòÍøÂçµÄ¹ÜÀíºÍά»¤

    ÁãÅäÖÃ

    Ö§³ÖCWMP(TR069)ЭÒé±ê׼ЭÒé

    ¹ÜÀíÌØÐÔ

    SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢sFLOW

     

    Õ¹¿ªÏêϸ²ÎÊý

    ×ÊÔ´ÖÐÐÄ

    Ó¦Óð¸Àý
    ¼¼Êõ²©ÎÄ
    ÊÛºóÎĵµ

    ³£¼ûÎÊÌâ

    ÎÒÒªÌáÎÊ
    È«²¿
    µçÔ´(1)
    Èý²ã½»»»»ú(2)
    »·Íø½»»»»ú(1)
    »·Â·¼ì²â(1)
    ½»»»Íø°å(1)
    ¹«º£²Ê´¬¡¤6600 2022Äê07ÔÂ25ÈÕ
    ¸Ã¿î½»»»»úÊǼ¸²ã½»»»»ú£¿
    ÓÐÓÃ 138 ÎÞÓÃ 19

    Èý²ãµÄ£¬RG-S2910XS-E¡¢RG-S2910-H¡¢RG-S2910G-P¡¢RG-S2910V2¡¢RG-S2910-LµÈϵÁн»»»»ú¶¼ÊÇÈý²ã½»»»»ú¡£

    ¹«º£²Ê´¬¡¤6600 2022Äê07ÔÂ25ÈÕ
    ÐèÒª»·Íø½»»»»ú£¬ÓÐÍÆ¼öµÄÐͺÅÂð£¿
    ÓÐÓÃ 70 ÎÞÓÃ 3

    ÎÒ˾֧³Ö“ERPSЭÒ锵Ľ»»»»ú¶¼ÊÇ»·Íø½»»»»ú£¬ÈçRG- S2900G-E V3 ºÍ RG-S2910XS-EϵÁÐǧÕ×½»»»»ú¡£

    Õ¹¿ªÈ«²¿
    Èç¹ûÄúÐèÒª¸ü¶à²úÆ·¼¼Êõ×Éѯ
    ¾ßÌåÐÔÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈçºÎ¹æ»®²¿ÊðÓëÅäÖã¿
    Á¢¼´×Éѯ

    ·µ»Ø¶¥²¿

    ÊÕÆð
    ÎĵµAIÖúÊÖ
    ÎĵµÆÀ¼Û
    ¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
    Äú¶Ôµ±Ç°Ò³ÃæµÄÂúÒâ¶ÈÈçºÎ£¿
    ²»Õ¦µÎ
    ·Ç³£ºÃ
    ÄúÂúÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
    Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
    Ϊ¾¡¿ì½â¾öÎÊÌ⣬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
    ÓÊÏä
    ÊÖ»úºÅ
    ¸ÐлÄúµÄ·´À¡£¡
    ÇëÑ¡Ôñ·þÎñÏîÄ¿
    ¹Ø±Õ×Éѯҳ
    ÊÛǰ×Éѯ ÊÛǰ×Éѯ
    ÊÛǰ×Éѯ
    ÊÛºó·þÎñ ÊÛºó·þÎñ
    ÊÛºó·þÎñ
    Òâ¼û·´À¡ Òâ¼û·´À¡
    Òâ¼û·´À¡
    ¸ü¶àÁªÏµ·½Ê½
    ¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿