¹«º£²Ê´¬¡¤6600(ÖйúÓÎ)¹Ù·½ÍøÕ¾

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·£¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¢¼´ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨·¢²¼
Ô¤Ô¼Ö±²¥
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ

RG-S6220ϵÁн»»»»úDCB¼¼Êõ½âÎö

DCB¼¼ÊõµÄµ®ÉúʹµÃÒÔÌ«ÍøÐ­Òé¿ÉÒÔʵÏÖ²»¶ª°üµÄ´«Ê䣬ͬʱʹµÃFCЭÒéÔÚÒÔÌ«ÍøÖеĴ«Êä³ÉΪ¿ÉÄÜ¡£¹«º£²Ê´¬¡¤6600ÍøÂçÊý¾ÝÖÐÐÄTOR½»»»»úRG-S6220ϵÁÐÆ¾½èÆä×ÔÉíµÄ¼¼ÊõÓÅÊÆ£¬¿ÉÖ§³ÖDCB¼¼Êõ×壬³ý´ËÖ®Í⻹֧³ÖFC¡¢FCoE¡¢IPÍøÂç½ÓÈ룬Âú×ã´óÐÍÊý¾ÝÖÐÐÄÈÚºÏÍøÂç½ÓÈë½»»»»úµÄÐèÇó¡£

  • ·¢²¼Ê±¼ä£º2014-08-21

  • µã»÷Á¿£º

  • µãÔÞ£º

·ÖÏíÖÁ

ÎÒÏëÆÀÂÛ

ÒÔÌ«Íø×÷ΪһÖÖ¾¡Á¦·þÎñµÄÍøÂçÄ£ÐÍ£¬ÍøÂ緱æʱ¿ÉÄÜ·¢Éú¶ª°ü»ò´«Êä¹ÊÕÏ£¬ÓÉÓÚ´«Í³ÒÔÌ«Íø²»¿É¿¿µÄ´«ÊäÌØÐÔ£¬Òò´Ë²»ÊʺÏÔÚ´æ´¢ÐÅÏ¢´«Êä¹ý³ÌÖÐʹÓá£ÀýÈ磺¹«¹²°²È«³¡ËùµÄ¼à¿ØÂ¼Ïñ£¬ÓÐÑо¿±íÃ÷£¬Ò»¸öÈËÂÓ¹ýÒ»¸ö¼à¿ØÉãÏñ»ú²»µ½Ò»ÃëÖÓ£¬Èç¹û¹Ø¼üÊý¾ÝÔÚ´«Êä¹ý³ÌÖжªÊ§£¬¾Í»á¸øÎ´À´µÄµ÷²éȡ֤Ôì³É¼«´óÀ§ÈÅ¡£

ΪÁËʹ¹âÏËͨµÀ´«ÊäÊý¾Ý¿ÉÒÔÔÚÒÔÌ«ÍøÉÏ´«Ê䣬·¢Õ¹³öÁËFCoE¢ÙЭÒé¡£µ«ÊÇ£¬´«Í³µÄÒÔÌ«ÍøÊǿ϶¨ÊÇÎÞ·¨³ÐÔØ¹âÏËͨµÀÊý¾Ý´«ÊäµÄ£¬ÒÔÌ«ÍøÓ¦¸Ã·¢Õ¹³ÉΪӵÓÐ×èÈû¹ÜÀíºÍÁ÷Á¿¿ØÖƹ¦ÄܵĵÍÑӳٵĺͲ»¶ªÆúÊý¾Ý°üµÄ´«Êä¼¼Êõ£¬×îÖÕ·¢Õ¹³ÉÔöÇ¿Ð͵ÄÒÔÌ«Íø¡£

ËùνÔöÇ¿ÐÍÒÔÌ«Íø£¬²¢²»ÊÇÔÚ´«Í³ÒÔÌ«Íø»ù´¡ÉÏ£¬Ìá³öеı¨ÎÄ·â×°¸ñʽ£¬¶øÊÇÓÉIEEEÊý¾ÝÖÐÐÄÍøÇÅ(Data Center Bridge£¬¼ò³ÆDCB)¹¤×÷×éÌá³öһϵÁÐÒÔÌ«ÍøÀ©Õ¹Ð­Ò飬À´ÔöÇ¿´«Í³ÒÔÌ«Íø´«ÊäµÄ¿É¿¿ÐÔ¡£ÔöÇ¿ÐÍÒÔÌ«ÍøÖ÷ÒªÓÐÁ½¸öÌØÕ÷£ºµÚÒ»¸öΪÔÚÒÔÌ«Íø»ù´¡ÉϽøÐÐÀ©Õ¹£¬Ö§³Ö½«ÉÏÊöÈýÀàÍøÂçÕûºÏÆðÀ´£»µÚ¶þ¸öΪ֧³ÖÁ÷³©´«Ê䣬´Ó¶ø¿ÉÒÔÖ§³ÖÄÇЩ¶Ô´«Êä¿É¿¿ÐÔÒªÇ󼫸ߵķþÎñ¡£

IEEEÊý¾ÝÖÐÐÄÍøÇŹ¤×÷×éÕýÔÚ¶¨ÒåµÄ±ê×¼ÈçÏ£º

  • ÓÃÓÚ»ùÓÚÓÅÏÈ´ÎÐòµÄÁ÷Á¿¿ØÖƵÄ802.1Qbb±ê×¼£¨¼´PFC¢Ú¼¼Êõ£©£»
  • ÓÃÓÚ³åͻ֪ͨµÄ802.1Qau±ê×¼£¨¼´CN¢Û¼¼Êõ£©£»
  • ÓÃÓÚÔöÇ¿µÄ´«ÊäÑ¡ÔñµÄ802.1Qaz±ê×¼£¨¼´ETS¢ÜºÍDCBX¢Ý¼¼Êõ£©

ÔÚDCEÖУ¬FC¢ÞÖ¡½«Ó³Éäµ½ÒÔÌ«ÍøÉÏÀ´½øÐгÐÔØ£¨FCoE±ê×¼£©¡£´«Í³µÄFCÌṩÁ÷¿Ø»úÖÆ£¬±£Ö¤ÎÞ¶ª°ü£¬²¢ÇÒ´«Í³µÄFC¶ÔÓÚʱÑÓµÄÔö¼Ó/±ä»¯»òÕß¶¶¶¯·Ç³£Ãô¸Ð¡£

¶ø´«Í³µÄÒÔÌ«ÍøÂç¿ÉÒÔÈÝÈÌÒ»¶¨µÄ¶ª°üºÍʱÑӱ仯/¶¶¶¯¡£ËùÒÔ£¬IEEE¶¨ÒåÁËһϵÁбê×¼£¬¹æ·¶DCE¶ÔÓÚ´«Í³ÒÔÌ«ÍøÔöÇ¿£¬Ö÷Òª°üÀ¨£º

  • 802.1Qbb Priority Flow Control(PFC)£º

´«Í³µÄÒÔÌ«ÍøÊÇÕûÌõÁ´Â·½øÐÐÁ÷¿ØµÄ¡£802.1QbbÊÇ»ùÓÚÓÅÏȼ¶µÄÁ÷¿Ø±ê×¼¡£ÔÚÒ»ÌõÎïÀíÁ´Â·ÉÏ£¬·Ö³ÉÁË8¸öÐéÄâͨµÀ£¬Ã¿Ò»¸öͨµÀ·ÖÅäÒ»¸öÓÅÏȼ¶¡£ÕâÑùÔÚÒ»ÌõÁ´Â·ÉÏ¿ÉÒÔ³ÐÔØ¶àÖÖÒµÎñÀàÐÍ£¬°üÀ¨FCoEºÍ·ÇFCoEµÄÒµÎñ¡£µ±·¢ÉúÓµÈûʱ£¬½ÓÊÕ¶Ë¿ÉÒÔÔÚÌØ¶¨µÄÓÅÏȼ¶ÐéÄâͨµÀÉÏ·¢ËÍXOFFºÍXONÖ¡£¬ÒÖÖÆ»òÕß¼ÌÐøÌØ¶¨µÄÒµÎñ£¬±£Ö¤¸ßÓÅÏȼ¶»òÕßʱÑÓÃô¸ÐµÄÒµÎñµÄ´«Êä¡£

ͼ1 PFC¼¼ÊõÔ­Àí

  • 802.1Qaz Enhanced Transmision Selection(ETS)£º

±£Ö¤²»Í¬·þÎñ¼¶±ðÉϵĶàÖÖÁ÷Á¿ÀàÐ͵ÄÖÊÁ¿¡£ÔÚDCBÉϵÄÒµÎñÖУ¬¼ÆËãÒµÎñÊÇʱÑÓÃô¸ÐµÄÒµÎñ£¬SANÒµÎñÊǶԶª°üÃô¸ÐµÄÒµÎñ£¬¶øIPÒµÎñÊÇ¿ÉÒÔÔÊÐíÒ»¶¨µÄ¶ª°üºÍʱÑÓ¡£Á´Â·ÉϵÄÒµÎñ¿ÉÒÔ·ÖΪÈô¸É¸öÓÅÏȼ¶×飬²¢ÇÒ¶¨Òåÿ¸öÓÅÏȼ¶×éµÄ´ø¿íÊôÐÔ¡£ÖØÒªµÄÒµÎñ£¬±ÈÈç´æ´¢ÍøÂçÊý¾Ý±»¸³Óè¸ßÓÅÏȼ¶£¬±£Ö¤´ø¿í¡£µÍÓÅÏȼ¶ÒµÎñÖ»ÄÜÔÚ¸ßÓÅÏȼ¶ÒµÎñ´ø¿í²»Õ¼ÓõÄÇé¿öÏ£¬²ÅÄÜʹÓ÷ÖÅä´ø¿íÖ®ÍâµÄ¶îÍâ´ø¿í¡£


ͼ2 ETS¼¼ÊõÔ­Àí

  • Congestion Notification£¨CN£©£º

ÔÚ´«Í³µÄÒÔÌ«Íø»·¾³ÖУ¬ÍøÂç´«Êä¹ý³ÌÖУ¬µ±ÍøÂçÁ÷Á¿´ïµ½×î´ó´ø¿íºó£¬²»¿ÉÄܱ£Ö¤ËùÓÐÁ÷Á¿µÄ´«Ê䣬ֻÄܽ«²¿·ÖÁ÷Á¿¶ªÆúµô¡£ÎªÁ˱£Ö¤Êý¾ÝÁ÷ÔÚ´«Êä¹ý³ÌÖв»±»¶ªÆú£¬¸ùÔ´µÄ°ì·¨Í¨ÖªÊý¾Ý·¢ËÍÔ´¶Ë£¬½µµÍÊý¾Ý·¢Ë͵ÄËÙÂÊ¡£»ùÓÚÓµÈûͨ¸æµÄ802.1Qau±ê×¼£¬¾ÍÊÇÔÚÕâÖÖ±³¾°Ï³öÏÖ£¬·þÎñÓÚÔöÇ¿ÐÍÒÔÌ«Íø£¬ÓÃÓÚÌá¸ßÒÔÌ«Íø´«ÊäµÄ¿É¿¿ÐÔ¡£


ͼ3 CN¼¼ÊõÔ­Àí

  • Data Center Bridging eXchange Protocol£¨DCBX£©£º

ÕâÊÇIEEE Link Layer Discovery Protocol(LLDP)µÄÀ©Õ¹£¬¿ÉÒÔÔÚÁ´Â·½¨Á¢µÄʱºò½»»»Á½¶ËÉ豸µÄÄÜÁ¦²ÎÊý£¬±ÈÈçÊÇ·ñÖ§³ÖPFC£¬ÒÔ¼°802.1QazÓÅÏȼ¶×é¡£


ͼ4 DCBX¼¼ÊõÔ­Àí

½áÊøÓDCB¼¼ÊõµÄµ®ÉúʹµÃÒÔÌ«ÍøÐ­Òé¿ÉÒÔʵÏÖÁ÷³©µÄ´«Ê䣬ͬʱʹµÃFCЭÒéÔÚÒÔÌ«ÍøÖеĴ«Êä³ÉΪ¿ÉÄÜ¡£¹«º£²Ê´¬¡¤6600ÍøÂçÊý¾ÝÖÐÐÄTOR½»»»»úRG-S6220ϵÁÐÆ¾½èÆä×ÔÉíµÄ¼¼ÊõÓÅÊÆ£¬¿ÉÖ§³ÖDCB¼¼Êõ×壬³ý´ËÖ®Í⻹֧³ÖFC¡¢FCoE¡¢IPÍøÂç½ÓÈ룬Âú×ã´óÐÍÊý¾ÝÖÐÐÄÈÚºÏÍøÂç½ÓÈë½»»»»úµÄÐèÇó¡£

¢Ù FCoE£ºFiber Channel Over Ethernet ÒÔÌ«Íø¹âÏËÐŵÀ

¢Ú PFC: Priority Flow Control, 802.1Qbb,»ùÓÚÓÅÏȼ¶µÄÁ÷¿Ø

¢Û CN: Congestion Notification£¬802.1Qau£¬ÓµÈûͨ¸æ

¢Ü ETS£ºEnhanced Transmision Selection, 802.1Qaz,ÔöÇ¿´«ÊäÑ¡ÔñЭÒé

¢Ý DCBX£ºData Center Bridging eXchange Protocol£¬802.1Qaz£¬Êý¾ÝÖÐÐÄÍøÇŽ»»»Ð­Òé

¢Þ FC£ºFiber Channel£¬¹âÏËÐŵÀ

Ïà¹Ø±êÇ©£º

µãÔÞ

¸ü¶à¼¼Êõ²©ÎÄ

ÈκÎÐèÒª£¬ÇëÁªÏµÎÒÃÇ

·µ»Ø¶¥²¿

ÊÕÆð
ÎĵµAIÖúÊÖ
ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶Ôµ±Ç°Ò³ÃæµÄÂúÒâ¶ÈÈçºÎ£¿
²»Õ¦µÎ
·Ç³£ºÃ
ÄúÂúÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
Ϊ¾¡¿ì½â¾öÎÊÌ⣬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
¸ÐлÄúµÄ·´À¡£¡
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´À¡ Òâ¼û·´À¡
Òâ¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿